SLDL5900 Gamma particle ash meter system

 Measurement accuracy  Low ash coal (ash ) 15% ), basic error: ± 0.5%
 Medium Ash Coal (Ash 15%~30% ), basic error: ± 1.5%
 High ash Coal (ash ) 30% ), basic error: ± 2.5%
 Conveyor Belt  Require the thickness of the seam quality (beam position) on the  conveyor  belt to be greater than 2.5g/cm²
 Water impact  Moisture Change 1% , ash measurements generally vary approximately   0.05% (related to coal species)
 Stability  maximum deviation of measuring support and mean is no more than ±  0.5%
 Adaptation range of coal  species  Not limited to, but for a variety of coal needs to be calibrated separately
 Environmental requirements  -5 íŠ ~50 íŠ Relative Humidity:90% under
 Communication mode  4~20ma,hart,modbus , Profibus PA , Foundation  FIELDBUS,GPRS/CDMA  Remote
 Certification  Ce,emc,ce SAFETY,FCC Part 15,IP67