Products

Blocked Chute Protection Switches

SLDL5195 FM Radar Level Meter

Type:SLDL5195 Frequency: 120GHz Measuring range: 150m Antenna material: PTFE, PFA Process connection: thread, flange Process temperature: -196...+800C Process pressure: -1...160 bar Measurement deviation: 0.5mm Signal output: 4...20mA/HART

More Information


Blocked Chute Protection Switches

SLDL5228 Radar level gauge

Type:SLDL5228 Application: Solids under the toughest process conditions Measuring range: 80m Antenna material: 304,316L Process connection: thread G1A, flange Process temperature: -40...+800C Process pressure: -1...100 bar Measurement devi

More Information


Blocked Chute Protection Switches

SLDOP&AT Angle Travel Electric Actuator

Type:SLDOPAT Output twist: 10-20000Nm Output angle: 90 Switching time: 2~155s Ambient temperature: -30C~+70C Relative humidity: 95%, 25C Vibration rating: 1g, 10Hz~1000Hz Working time: S2 working system, rated working time is 30 minutes Fl

More Information


Blocked Chute Protection Switches

SLDOP & LT Executive Electric Actuators

Type:SLDOPLT Output stroke: 22-10mm Maximum force: 500~25000N Travel speed: 0.64~3.85s/mm Ambient temperature: -30C~+70C Relative humidity: 95%, 25C Vibration rating: 1g, 10Hz~1000Hz Working time: S2 working system, rated working time is 3

More Information


Blocked Chute Protection Switches

SLD-OPQTB Button control type

LEDdisplay opening, on/off/fault information etc On/off/stop site button in site Close control/remote control/fobidden hole can be switched Infrared remote control (optional) Support modbus, Profibus

More Information


Blocked Chute Protection Switches

SLDA5700 Microwave Multi-parameter Analysis System

Transmission frequency 10GHz~26GHz automatically selected according to material properties Measuring range Moisture content: 0~95%, speed: 50~500mm/s, height: 400~2400mm Microwave radiation angle 30 Measurement resolution Moisture content:

More Information


Blocked Chute Protection Switches

SLDL5900 Gamma particle ash meter system

Measurement accuracy Low ash coal (ash ) 15% ), basic error: 0.5% Medium Ash Coal (Ash 15%~30% ), basic error: 1.5% High ash Coal (ash ) 30% ), basic error: 2.5% Conveyor Belt Require the thickness of the seam quality (beam position) on th

More Information


Blocked Chute Protection Switches

SLDL7110 (hard tube type) magnetostrictive liquid level gaug

Type:SLDL7110(hard tube type) Oil level measurement accuracy: 0.5mm Water level measurement accuracy: 0.5mm Temperature measurement accuracy: 0.2C Boundary measurement accuracy: 1mm High resolution: 0.01mm Measuring range: 0~5m Temperature

More Information


Blocked Chute Protection Switches

SLDL7120 (Hose Type) magnetostrictive liquid level gaug

Type:SLDL7120(Hose Type) Oil level measurement accuracy: 0.5mm Water level measurement accuracy: 0.5mm Temperature measurement accuracy: 0.2C Boundary measurement accuracy: 1mm High resolution: 0.01mm Measuring range: 0~20m Temperature poi

More Information


Blocked Chute Protection Switches

SLDF7110 (integrated) electromagnetic flowmeter

Type:SLDF7110 (integrated) Nominal diameter: 15~2000mm Flow rate range: 0-10m/s Accuracy: 0.5%R, 1% (DN20 or less) Medium conductivity: theoretical value 5uS/cm, actual use 30uS/cm Nominal pressure: standard 1.0MPa DN15-DN800 Optional 1.6M

More Information